How to repair an air conditioning and momenclaturas

First we observe that the fault is detected on the computer if a power failure mail or refrigerator.

observed in the case of an acoustic signal, light or any entry in the display we see the manufacturer's installation manual.
If this machine does not have this type of failure can have a malfunction:
Due to lack of load or overload: this will be indicated by the bridge gauge or analyzer, if the pressure is low in the circuit below normal (see table coolant pressure), chances are we've got a leak, excess fluid in the circuit can detect a current clamp comparing actual consumption with the theoretical data plate of the outdoor unit, a machine with enough excess fluid consumed over what makes the film.
cooling line is frozen: we see that we have no lack of charge or release (you can also note the lack of load checking liquid line is hot or cold and cold gas is or temp. environment.
The machine is in depression: usually happens to us when we have a blockage in the circuit so the gap is made to the circuit through the compressor.
For escape: if the machine has been working to verify whether a patch of oil, which does not indicate the approximate point where this, or use electronic devices for the detection of different refrigerants, but the best method is a soap and water as you have pressure within the circuit.

Electrical part: see immediately if we tension in the indoor unit if we do not start this, o comprobar si hay tensión en la unidad exterior si no nos arranca.
Otra prueba es comprobar las bobinas del compresor con un tester para comprobar el estado de este, y realizar una comprobación al cableado de la máquina.

Parte electrónica: si lo que no arranca es la unidad interior comprobar fusible de placa y transformador si se dispones de este, revisar el cableado y comprobar que todo esta correcto.
Si se ha comprobado lo anterior y la máquina no presenta una señal de alarma, automáticamente cambiar placa.
En el caso de que aparezca una señal de alarma esta puede ser por: fallo en el interconexionado de la placa, sonda de inmersión de la unidad interior o exterior, sonda environment outside or inside the unit, failed fans, etc ...

Especially when you perform a repair to remain calm and think positively because there is no irreparable machine.

I found on several occasions that the installers do not make minimum facilities for example if the split is separated by a wall of the condenser tube perform a cold installation of less than 40 cm, then we can find eye problems including noise problems refrigerator so it is advisable to make a return to copper tube in a place that is not very visible for example behind the condensing unit. I have also found
installers who will do minimum tool-repair as an analyzer (gauge bridge), a thermometer or a clamp (These three tools are essential in the case of maintenance personnel of any company, as indicated in a previous article we found problems with the analyzer refrigerators, with the clip too, and also electrical problems with the thermometer ensures the proper performance of the air conditioning.
So before you call any service center depending on the problem we see at high pressures and low differential temperature and use of both cold and heat, as with all these data, the call center We can provide a solution to the problem. Now in winter
commonly encountered problems is lack of frozen cargo in the outdoor unit, which probes immersion field units tell them if you have freezing weather, this is solved by adding charge provided that perform this operation according to manufacturer additional charge g / m.
If defrost problem of excessive and persistent freezing kits can be used to defrost or just a very simple kits ESISTO silicon with a resistance, a thermostat and a probe, this resistance is rolled to the bottom of the battery condensing unit and the thermostat probe the environment for example in the contrary to the fan and the thermostat set at 5 º C eg positive when the temperature drops acts of resistance by avoiding the creation of Frost (these kits have a low power consumption).
Another problem is investment valves (four-way valve), or your coil for four-way valve usually with a few taps is usually solved and remaining stuck in last place or if that fails have change, or the problem we can be found in the spool valve has been bypassed so the check and change it.
To determine these two problems or we do it with the forceps or with the analyzer.
Another problem is the freezing of the coolant bottle to carry the burden of a team that freezing slows us over the refrigerant charge therefore recommend the use of a kit that is placed around the bottle of low weight that slows freezing bottle and allows us to load in less time, this kit TOOLS ITE factory.
But above all it must fix the installer as is the eyes of technical call center.

For more information:

alberto@aricclima.com

Ultralight Backpacking Blog

Terms used in air conditioning condensate



Definitions and terms used in air conditioning.

Kilocalorie : The amount of energy needed to heat one gram of water one degree Celsius.
BTU is the energy that must be subtracted from one gram of water one degree centigrade to cool.
COP: Coefficient of abbreviations Of Performance is a coefficient of efficiency, and is the result of dividing the cooling capacity in watts by the power absorbed in watts, so the unit is expressed in W / W
EER : of abbreviations Energy Efficiency Ratio, is a power coefficient result of dividing the cooling capacity in Kcla / k by the power absorbed in watts, so the unit is expressed in Kcal / h / W. Energy Labelling
: Electrical appliances are marked with a letter A, B, C, to G-class brand energy or energy class, where G had the lowest efficiency and to the highest.
The energy label for appliances intended to show consumers the difference between the consumption of two devices with similar performance. Refrigerant
: the fluid used in the transmission of heat in a refrigeration system absorbs heat at low temperature and pressure, temperature and pressure cediéndolo higher. This process takes place, usually with fluid status changes.
The most used are the R410A refrigerant is azeotropic azeotropic almost behaves as a pure substance (must be loaded in the liquid phase) and non-azeotropic R407c consists of several gas phase components behave differently (must be loaded in liquid phase).

mediated Units:
cooling capacity of an air conditioning can be measured in BTU
: the British acronym Thermical Unit is the amount of heat required to raise the temperature of one pound of water one degree Fahrenheit (It's the same definition as Kcal. But utilizandos English units of measurement).
W: Watt is another way of expressing the cooling capacity
Kilocalorie : is another way of expressing the cooling capacity, and the most usual.

Therefore these three units say the same thing in different units, easily change a few simple unit conversion factors.

To switch BTU / h Kcal / h multiply by 0.252 kcal
To move / ha BTU / h divided by 0.252
To go from W / ha Kcal / h multiply by 0.86 Kcal
To move / ha W / h divided by 0.86

dBA: A-weighted decibels, a noise magnitude unit to compare the different sounds harmful to the human ear (and therefore serves to be weighted comparison between the sound of an air machine to another).
In this magnitude we can distinguish the output level (volume), and level of intensity (amplitude).

alberto@aricclima.com

What Are The Meanings Of Jelly Rings

Cooler Bottle Belt


Then I discuss a product that provides a solution to the problems of condensate from air conditioning machines, once these machines they tend to be condensed to a unsightly drum or bucket, which often forget to empty. Well
I present a product to hit the market and its function is to eliminate the annoying evaporating condensed , preventing lead to a drain or container. This team works
connecting directly to the mains and equipment has a capacity of 1.5 liters / hour or what is equal, the power of dehumidification a 300th machine Kcal / h 3.5 KW or 12000 BTU , the equipment removed, evaporated and condensed the inside that has a pair of spaced electrical that it removes condensate dissociation, this unit has no resistance so the team has an average consumption of 1.5 to 2.5 Amps being the highest peak consumption 5 amps once removes condensate pairs remain open and not consume.
has a cap on the bottom for regular maintenance.
dissipation team condensate is certified by CE and IEC thus meeting international safety certificates.

Leg Pain During Ovulation

or charging cylinder


400W Belt to wrap the bottle or cylinder of refrigerant charge can be or connect to the electricity or external machine, the belt is placed around the bottle of refrigerant charge and what we do is to avoid sudden drop in coolant temperature and facilitate the departure of this was our circuit, a load refrigerant in the winter we usually take a lot of work, with this belt shortened much time of refrigerant and avoid freezing, the kit comes with springs in order to adjust the belt to the different sizes of bottle and always maintain good contact with this.

www.aricclima.com

Brazilian Hollywood Wax

anti freezing winter Kit




Kit winter, all we ever have ice cream in an outdoor unit, as this system is to prevent the unit from freezing outside.
The kit consists of a low resistance of 1.5 meters long which is mounted on the bottom of the outdoor unit silicone rolling resistance to the battery, this resistance is connected to a thermostat, which acts as the temperature environment detected by the probe is below the thermostat setpoint, the act makes the resistance, thus avoiding the freezing of the outdoor coil (outdoor unit) operating the heat pump.